Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Management of spontaneous pneumothorax often involves intercostal chest drain (ICD) insertion. Determining when to remove the ICD is controversial, with significant variation in practice. Establishing optimal ICD management in pneumothorax could reduce morbidity and improve cost-effectiveness. RESEARCH QUESTION: Do ICD removal strategies, including clamping and use of digital air leak devices, impact the risk of pneumothorax recurrence, need for repeat pleural procedures, or length of stay? STUDY DESIGN AND METHODS: We conducted a multicenter retrospective analysis of patients requiring ICD insertion for spontaneous pneumothorax from May 2021 to October 2023. Data were collected on demographics, clinical course, ICD removal strategy, pneumothorax recurrence (early and late), and repeat pleural intervention. RESULTS: A total of 791 admissions from 27 centers were included. The 30-day recurrence of pneumothorax was 13.0% (n = 103). Clamping trials were undertaken in 32.6% of cases (n = 258), but recurrence of pneumothorax was not significantly different in clamped compared with nonclamped groups (14.0% vs 12.6%, respectively; P = .67). Clamping identified pleural air reaccumulation in 24 episodes (9.3% of the clamped group). Of 234 cases where clamping did not identify air leak, 35 patients (15.0%) developed recurrent pneumothorax. Of the 533 patients whose drains were not clamped, 67 (12.6% of the group) developed recurrence. The median length of stay was 6 (clamped) vs 5 days (nonclamped) (P = .08). Adverse events associated with clamping were few (n = 6), but included tension pneumothorax (n = 1). Digital air leak devices combined with clamping resulted in the lowest rates of pneumothorax recurrence; however, this approach was rare (n = 24, 0.0% recurrence within 7 days). INTERPRETATION: Our results indicate that recurrent pneumothorax after ICD removal is a common complication. Clamping trials are safe but do not appear to be associated with reduced rates of recurrent pneumothorax. An ultracautious approach using digital air leak devices in combination with clamping could represent a viable strategy in selected patients.

More information Original publication

DOI

10.1016/j.chest.2025.10.027

Type

Journal article

Publication Date

2026-03-01T00:00:00+00:00

Volume

169

Pages

849 - 858

Total pages

9

Keywords

clamping, digital suction, pneumothorax, tension pneumothorax, Humans, Pneumothorax, Chest Tubes, Device Removal, Male, Female, Retrospective Studies, Adult, Middle Aged, Recurrence, Drainage, Length of Stay